1
HVLP Compliant Spray gun
Low Volume Low Pressure
Important
Be sure to observe warnings and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
Be sure to observe following marked items which are especially important.
Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or property
damage.
Important
Indicates notes which we ask you to observe. The safety precautions in this instruction manual are the minimum
necessary conditions. Follow national and local regulations regarding fire prevention, electricity and safety as well as
your own company regulations.
Main specifications
Recommended conditio
Model
Type of
feed
Nozzle
orifice
φmm (in)
Air cap
Set
Mark
1 Atomizing
air pressure
MPa (bar /PSI)
A
ir pressure inside
air cap
MPa (bar /PSI)
2
Fluid output
ml/min
Air
consumption
l/min (cfm)
2
Pattern width
mm (in)
Air & fluid
connection
Mass
g (lbs)
LPH-80-042G
0.4(0.016) 8 40(1.6)
-062G
0.6(0.024) 25 60(2.4)
-082G
0.8(0.032) 45 80(3.2)
-102G
1.0(0.039) 55 100(3.9)
-122G
1.2(0.047)
E2
0.09
(0.9/ 13)
80
50 (1.8)
120(4.7)
-044G
0.4(0.016) 10 55(2.1)
-064G
0.6(0.024) 30 80(3.1)
-084G
0.8(0.032) 45 100(3.9)
-104G
1.0(0.039) 60 130(5.1)
-124G
Gravity
1.2(0.047)
E4
0.10
(1.0/ 14)
0.07
(0.7 /10)
75
60 (2.2)
140(5.5)
Air
1/4
NPS1/4
Fluid
1/8
205
(0.45)
1. Atomizing air pressure means air pressure at gun inlet when trigger is pulled and air flows
2.Tested with 16sec / Ford cup #4 automotive repair paint.
This Anest-iwata spray gun kit complies to ATEX
regulations 94/9/EC,
Protection level
2 G XSuitable for use in Zones 1 and 2.
X marking
Any static electricity discharge from the spray gun
is to be diverted to the grounded the conductive
air hose as stipulated
.
LPH-80
Important specifications
Max. Pressure
0.68
MPa
/
6.8
bar
/
98
PSI
Noise level
60.3
(A)
Spray condition Recommended
Measuring point
1m backwards from gun,
1.6
m height
Max. Temperature
Atmosphere
5℃~40℃
Air
Fluid
5℃~43℃
This manual contains IMPORTANT WARNINGS and INSTRUCTIONS.
Equipment in this manual is exclusively for painting purposes.
Do not use for other purposes.
The operator shall be fully conversant with the requirements stated in this
instruction manual including important warnings, cautions and operation and
correct handling.
Read and understand the instruction manual, before use and retain for
reference.
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - HVLP Compliant Spray gun

- 1 - HVLP Compliant Spray gun Low Volume Low Pressure Important Be sure to observe warnings and cautions in this instruction m

Seite 2 - How to connect

- 2 - Safety precautions Fire and explosion 1. Spark and open fl

Seite 3

- 3 - How to operate Recommended paint viscosity differs according to paint property and painting conditions. 12 to 20 sec./Ford cup#4 is recomme

Seite 4 - Troubleshooting

- 4 - Parts list No. Description Q’ty 1 Air cap 1 2 Packing 1 3 Cover 1 4 Fluid nozzle 1 5 Fluid needle set 1 6 needle packing set 1 7 Need